g. Opti-ServeModel–"WTRDP" LED is on: Before engaging the water dispense

OptiServe sensor, check for the correct VDC from the locations given in the "Disengaged" column in the table below. If the VDC is different than in the table, replace CB. If the VDC is correct, engage the OptiServe sensor. "WTRDP" LED turns on. If not, confirm that the water dispense signal VDC matches the "Engaged" column in the table below. If not, replace the Opti-Serve sensor. If the VDC matches the "Engaged" column below and the "WTRDP" LED does not turn on, replace CB.

5VDC CB K7 Connector

Component

Pin # (Wire Color)

To

CB VDC Ground

Disengaged

Engaged

VDC Sensor Ground

#7 (R)

 

Red K4 pin closest

0VDC

0VDC

Water Dispense Signal

#8 (W)

To

0VDC

5VDC

to black K3

5VDC Power Supply

#9 (BK)

 

5VDC

5VDC

 

 

Red positive test lead to red K4 connector pin closest

to black K3

Red Positive Test Lead

Multimeter

5VDC

Black Negative

 

Test Lead

Control Board K7 Connector

connector

Water Dispense (BK)

 

(5VDC power)

 

Water Dispense (W)

Water Dispense (R)

(switch signal)

(VDC GND)

Fig. 4

22