Configuring the Setviews menu option programs

3.Create a program called EXP.ME2 with contents as shown. This program sets the numeric view options for the aplet, and runs the program that

you can use to configure the angle mode.

4.Create a program called EXP.ANG which the previous two programs call.

5.Create a program called EXP.S which runs when you start the aplet, as shown. This program sets the angle mode to degrees, and sets up the

initial function that the aplet plots.

In this section we will begin by configuring the VIEWS menu by using the SETVIEWS command. We will then create the “helper” programs called by the VIEWS menu which will do the actual work.

6.Open the Program catalog and create a program named “EXP.SV”. Include the following code in the program. (Text shown in italics below are comments only.)

Each entry line after the command SETVIEWS is a trio that consists of a VIEWS menu text line (a space indicates none), a program name, and a

number that defines the view to go to after the program has run its course. All programs listed here will transfer with an aplet when the aplet is transferred.

Programming

15-11