threshold

Initiates a configuration session by which to generate and log alarms for selected events. The system displays each event, its triggers, and sampling window one line at a time and prompts you for a value. For each parameter, enter a new value or press Enter to accept the current value shown in brackets. These parameters must be saved in a configuration and activated before they will take effect. Refer to the Config command for information about saving and activating a configuration. Table 47 describes the Set Config Threshold parameters. The switch will down a port if an alarm condition is not cleared within three consecutive sampling windows (by default 30 seconds). Reset the port to bring it back online. An alarm is cleared when the threshold monitoring detects that the error rate has fallen below the falling trigger.

Table 47 Set Config threshold parameters

Parameter

Description

 

 

Threshold Monitoring Enabled

Master enable/disable parameter for all events. Enables (True)

 

or disables (False) the generation of all enabled event alarms.

 

The default is False.

 

 

CRCErrorsMonitoringEnabled

The event type enable/disable parameter. Enables (True) or

DecodeErrorsMonitoringEnabled

disables (False) the generation of alarms for each of the

ISLMonitoringEnabled

following events:

LoginMonitoringEnabled

CRC errors

LogoutMonitoringEnabled

Decode errors

LOSMonitoringEnabled

 

ISL connection count

 

Device login errors

 

Device logout errors

 

Loss-of-signal errors

 

 

Rising Trigger

The event count above which a rising trigger alarm is logged.

 

The switch will not generate another rising trigger alarm for

 

that event until the count descends below the falling trigger

 

and again exceeds the rising trigger.

 

 

Falling Trigger

The event count below which a falling trigger alarm is logged.

 

The switch will not generate another falling trigger alarm for

 

that event until the count exceeds the rising trigger and

 

descends again below the falling trigger.

 

 

Sample Window

The period of time in seconds in which to count events

 

 

 

160 Command Line Interface