The following is an example of the Show Config Switch command:

McDATA4GbSAN #> show config switch

Configuration Name: default

-------------------

AdminState

Online

BroadcastEnabled

True

InbandEnabled

True

FdmiEnabled

True

FdmiEntries

1000

DefaultDomainID

98 (0x62)

DomainIDLock

False

SymbolicName

McDATA4GbSAN

R_A_TOV

10000

E_D_TOV

2000

PrincipalPriority

254

ConfigDescription

Default Config

ConfigLastSavedBy

Initial

ConfigLastSavedOn

Initial

InteropMode

Standard

The following is an example of the Show Config Threshold command:

McDATA4GbSAN #> show config threshold

Configuration Name: default

------------

Threshold Configuration Information

-----------------------------------

ThresholdMonitoringEnabled

False

CRCErrorsMonitoringEnabled

True

RisingTrigger

25

FallingTrigger

1

SampleWindow

10

DecodeErrorsMonitoringEnabled True

RisingTrigger

25

FallingTrigger

0

SampleWindow

10

ISLMonitoringEnabled

True

RisingTrigger

2

FallingTrigger

0

SampleWindow

10

LoginMonitoringEnabled

True

RisingTrigger

5

FallingTrigger

1

SampleWindow

10

LogoutMonitoringEnabled

True

RisingTrigger

5

FallingTrigger

1

SampleWindow

10

LOSMonitoringEnabled

True

RisingTrigger

100

FallingTrigger

5

SampleWindow

10