CLI commands

switch port

Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl

switch port <name>

Switch to the ethernet port context.

syslog

Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl

syslog

Switch to syslog context.

sensor server name

Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl

sensor server name <name>

Sets the IP address or hostname of the the RF Manager Server to connect to.

Parameters

Name

Specify the IP address of the the RF Manager Server or its hostname. If a

 

hostname is specified, the service controller must be able to resolve it via

 

DNS, that is, an entry must be created on the network DNS server that

 

points to the IP address of the RF Manager Server.

sensor server id

Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl

sensor server id <id>

Sets the server ID of the the RF Manager Server to connect to.

Parameters

ID

Specify the Server ID of the RF Manager Server to connect to. Set the

 

Server ID to 0 to have the service controller send a discovery request to all

 

active RF Manager Servers. The service controller will connect to the first

 

server that responds to the discovery request.

sensor discovery mode

Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl

sensor discovery mode (id ip)

Sets the method the service controller will use to communicate with the RF Manager Server.

Parameters

id

Connect using the Server ID of the RF Manager Server.

ip

Connect using the IP address or hostname of the RF Manager Server.

Description

For these methods to work, the following must be true:

„The service controller must be able to reach the RF Manager Server via a network connected to port 1 or port 2. For example, you should be able to ping the RF Manager Server IP address from the service controller.