Setup Menus

Screen Mapping

Factory default: 1024 (x) by 768 (y)

This option enables you to select the correct resolution for screen addressing when in Tek 4014 or Westward 2119 graphics modes.

For Tek 4014 mode select 1024 (x) by 768 (y) resolution (default).

For Westward 2119 mode select 1024 (x) by 784 (y) resolution.

Gin Terminators

Factory default: ^M^D (i.e. CR EOT)

This option enables you to specify the termination character(s) that follow a GIN address transmission. A maximum of 6 characters can be entered.

To change the current definition, delete the definition displayed in the text box and type in the new one, either as the control key character equivalent or the decimal value of the ASCII character(s).

For example, the ASCII character CR can be entered by typing the characters ^

and M, representing the keys Ctrl + M which, when pressed together would generate the CR code.

Decimal values are entered as three-digit numbers immediately preceded by an underscore character. Values with only two digits must be preceded by a zero. For example, the decimal value of CR is 13, so this would be entered as _013.

6-90