HP Sander 16500C manual OUTPolar, CommandINTermoduleOUTDrive 0NORMal1OPENcllctr

Models: Sander 16500C

1 252
Download 252 pages 12.2 Kb
Page 208
Image 208

INTermodule Subsystem

OUTDrive

OUTDrive

Command:INTermodule:OUTDrive {{0NORMal}{1OPENcllctr}}

See Also

Example

Query

Returned Format

Example

The OUTDrive command sets the Port Out BNC to put out either a normal (TTL-type) or open-collector signal. This corresponds to the Output field in the PORT IN/OUT Setup menu under the Intermodule menu.

The HP 16500C User’s Reference for more information about open collector signals.

OUTPUT XXX;":INTERMODULE:OUTDRIVE NORMAL"

:INTermodule:OUTDrive?

The OUTDrive query returns the current Port Out output setting.

[:INTermodule:OUTDrive] {10}<NL>

OUTPUT XXX;":INTERMODULE:OUTDRIVE?"

Command

Example

OUTPolar

:INTermodule:OUTPolar {{0HIGHtrue}{1LOWtrue}}

The OUTPolar command sets the Port Out BNC polarity. This command has the same effect as setting the Polarity field in the PORT IN/OUT Setup menu under the Intermodule menu.

OUTPUT XXX;":INTERMODULE:OUTP HIGH"

13–10

Page 208
Image 208
HP Sander 16500C manual OUTPolar, CommandINTermoduleOUTDrive 0NORMal1OPENcllctr, INTermoduleOUTDrive?