TGTctrl Subsystem

LASTstate

LASTstate

Command:TGTctrl:LASTstate<N> <state>

The LASTstate command sets a signal’s last state. LASTstate has no effect unless the signal type is sequence.

<N> An integer, 0 through 7, specifying signal.

<state> An integer, 1 through 7.

Example

OUTPUT XXX;":TGTCTRL:LAST2 4"

 

 

Query:TGTctrl:LASTstate<N>?

The query returns the current last state. For toggle and pulse signals, the last state is always 1.

Returned Format [:TGTctrl:LASTstate<N>] <state><NL>

Example

OUTPUT XXX;":TGTCTRL:LAST1?"

 

 