Configuring HP FTAM/9000

FTAM Parameters: ftam_parms

ft_no_of_recovery This parameter allows you to configure the number of recoveries that will be attempted on each file transfer. This will prevent looping of the recovery procedure. The value is only used if the ft_qos error class is set to 1 or 2.

FORMAT

decimal number

UNIT

number of times to attempt recovery

RANGE

1 - 99999

DEFAULT

5

OSICONF

no

DYNAMIC

yes

SCREEN

NA

FIELD

NA

ft_recovery_timer This parameter allows you to configure the time of delay required for the local FTAM responder to recover, before the recovery procedure begins. The timer is sent back to the FTAM initiator via the F-RECOVER response. The FTAM initiator will retry with an F-RECOVER request after the timer has expired. The value is only used if the ft_qos error class is set to 1 or 2.

FORMAT

decimal number

UNITseconds

RANGE 0 - 3600

58

Chapter 2