12.Insert the diskette that you created in step 1.
13.Press F3 and specify the path a:\novell\netware.
14.Follow the instructions on the panels to complete the installation of the driver. If you need to make any custom configuration changes to the driver, do so at this time.
15.Follow the instructions in the Novell manual Create an AUTOEXEC.NCF file. In addition to the instructions in the manual, add the following lines to the AUTOEXEC.NCF file, immediately after the IPX INTERNAL NET statement (if necessary, replace c:\nwserver with the actual location of the SERVER.EXE executable):
LOAD C:\NWSERVER\NBI.NLM
LOAD C:\NWSERVER\MSM.NLM
LOAD C:\NWSERVER\TOKENTSM.NLM
LOAD C:\NWSERVER\IBMTRPO.LAN NAME=IBMLS1 DATARATE=M16
Note: There will be existing LOAD and BIND IPX statements in the AUTOEXEC.NCF. Delete the LOAD statement (we have replaced it with the stated LOAD C:\NWSERVER\IBMTRPO.LAN statement).
Also, make any needed modifications to the existing BIND IPX statement. Refer to the ″Bind the Protocol to the LAN Driver″ section of the Novell manual for additional information.
See “Appendix D. Novell NetWare Server driver parameters” on page 65 for a complete list of parameters that can be specified on the LOAD IBMTRPO command in the AUTOEXEC.NCF file.
16.Press Esc and answer YES to save the new file to disk. Press Esc again to return to the server console.
17.Type the following commands from the server prompt to shut down the server and exit to DOS: down, and then exit.
18.Type the following commands, making sure that the diskette that you created in step 1 is inserted in drive A. Note that it will prompt you at each of the following files to ask if you want to perform a file overwrite; it is OK to overwrite these files.
COPY A:\NOVELL\NETWARE\NBI.NLM C:\NWSERVER COPY A:\NOVELL\NETWARE\MSM.NLM C:\NWSERVER COPY A:\NOVELL\NETWARE\TOKENTSM.NLM C:\NWSERVER COPY A:\NOVELL\NETWARE\IBMTRPO.LAN C:\NWSERVER COPY A:\NOVELL\NETWARE\IBMTRPO.LDI C:\NWSERVER
19.Go to the Novell server directory and enter server at the DOS prompt to restart the server.
20.Check for the following conditions to determine whether the adapter is working correctly and whether installation has been completed successfully:
vThe device driver files are loading successfully. There are no error messages.
vThe adapter LEDs indicate normal operation. Green ON, Amber OFF. See “Understanding the adapter LEDs and labels” on page 43.
If you experience problems, see “Chapter 4. Problem solving” on page 37.
For information concerning NetWare Server error messages, see “Appendix E. Novell NetWare Server messages” on page 71.