Table 2-1 POST Error Codes and Messages List

NOTE: To diagnose a problem, first find the BIOS error messages or codes in left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/FRU listed in right column is the most likely cause.

BIOS Error Codes,

 

Action/FRU

Messages

 

 

 

 

 

 

Floppy Disk(s) Fail (80)

1.

Re-connect floppy disk

 

 

drive

 

2.

Enter Configuration/

 

 

Setup Utility and load the

 

 

default settings.

 

3.

Floppy disk drive

 

4.

System board

 

 

 

Floppy Disk(s) Fail (40)

1.

Re-connect floppy disk

 

 

drive

 

2.

Enter Configuration/

 

 

Setup Utility and load the

 

 

default settings.

 

3.

Floppy disk drive

 

 

 

Hard Disk(s) Fail (80)

1.

Enter Configuration/

Hard Disk(s) Fail (40)

 

Setup Utility and load the

 

 

default setting

 

2.

Check IDE drive jumper.

 

 

See “3.5-In. Hard Disk

 

 

Drive Jumper Settings”

 

 

on page 117.

 

3.

IDE hard disk drive

 

 

power.

 

4.

IDE hard disk drive cable/

 

 

connection.

 

5.

IDE hard disk drive.

 

6.

System board

 

 

 

Hard Disk(s) Fail (20)

1.

Enter Configuration/

Hard Disk(s) Fail (10)

 

Setup Utility and load the

 

 

default setting

 

2.

IDE hard disk drive

 

 

power.

 

3.

IDE hard disk drive cable/

 

 

connection.

 

4.

IDE hard disk drive.

 

 

 

Hard Disk(s) Fail (08)

1.

Hard disk drive

 

 

 

Check Procedures 43