Table 2-3 Error Symptoms List

NOTE: To diagnose a problem, first find the error symptom in the left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/ FRU listed in right column is the most likely cause.

Error Symptoms

Action/FRU

 

 

Processor / Processor Fan

NOTE: Normally, the processor fan should be operative, and the processor clock setting should be exactly set to match its speed requirement before diagnosing any processor problems.

Processor fan does not run

1.

Ensure that the system is

but power supply fan runs.

 

not in power saving mode

 

 

and the “Stop CPU clock

 

 

in sleep state” is not set

 

 

to Yes. See “Power

 

 

Management” on page 5.

 

2.

With the system power

 

 

on, measure the voltage

 

 

of processor fan

 

 

connector FN2. Its

 

 

reading should be

 

 

+12Vdc. See “System

 

 

Board Jumpers and

 

 

Connectors” on page

 

 

109.

 

3.

Processor fan.

 

4.

System board.

 

 

 

Processor test failed.

1.

Processor.

 

2.

System board.

 

 

 

System Board and Memory

NOTE: Ensure that the memory modules are installed properly and the contact leads are clean before diagnosing any system problems.

Memory test failed.

1.

See “Memory” on page

 

 

65.

 

2.

System board

 

 

 

Check Procedures 45

Page 79
Image 79
IBM 2274 manual Error Symptoms List, Error Symptoms Action/FRU Processor / Processor Fan, System Board and Memory