POST Error Code FRU/Action
6XX
Not listed above. 1.Diskette Drive
2. SystemBoard
3. Risercard
4. External Drive Adapter
5. Diskette Drive Cable
6. PowerSupply
762
Math coprocessor
configuration error.
1.Run Setup
2. Processor
3. SystemBoard
7XX
Not listed above. 1.Processor
2. SystemBoard
962
Parallel port configuration
error.
1.Run Configuration
2. ParallelAdapter
(if installed)
3. SystemBoard
9XX 1.Printer
2. SystemBoard
1047 1. 16-Bit AT Fast SCSI
Adapter
107X
Check SCSI terminator
installation.
1.Check SCSI
terminator
installation.
2. SCSICable
3. SCSITerminator
4. SCSIDevice
5. SCSIAdapter
1101
Serial connector error,
possible system board
failure.
1.Run Enhanced
Diagnostics
1101, 1102, 1106,
1108, 1109 1.System Board
2. Any Serial Device
1107 1.Communications
Cable
2. SystemBoard
1102
Card selected feedback
error.
1.Run Enhanced
Diagnostics
1103
Port fails register check. 1.Run Enhanced
Diagnostics
2. SystemBoard
1106
Serial option cannot
be turned off.
1.Run Enhanced
Diagnostics
2. SystemBoard
1107 1. Serial Device Cable
2. SystemBoard
1110
Register test failed. 1. RunEnhanced
Diagnostics
2. SystemBoard
1116
Interrupt error. 1.Run Enhanced
Diagnostics
90 IBM PC 300/IntelliStation Vol 3 HMM