Diagnostic Error Code FRU/Action
030-000-XXX
SCSI interface Test Passed 1.No action
030-00X-XXX
030-01X-XXX
SCSI interface failure
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if
installed
5. System board
030-027-XXX
SCSI interface
Configuration/Setup error
1. SCSI signal cable
2. Flash the system
3. SCSI device
4. SCSI adapter card, if
installed
5. System board
030-03X-XXX
030-04X-XXX
SCSI interface error
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if
installed
5. System board
030-195-XXX
SCSI interface Test aborted
by user
1.Information
2. Re-start the test, if
need to
030-196-XXX
SCSI interface test halt,
error threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
030-197-XXX
SCSI interface test warning 1. Make sure
component that is
called out is enabled
and/or connected
2. Re-run test
3. Component that is
called out in warning
statement
4. Component under test
030-198-XXX
SCSI interface test aborted 1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to “Undetermined
problem” section.
030-199-XXX
SCSI interface test failed,
cause unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replace component
under function test.
035-000-XXX
RAID interface Test Passed 1.No action
IBM PC Enhanced Diagnostics error codes 13