POST Error Code FRU/Action
168
Alert on LAN2 error 1.Run Setup. Checkto
see that Ethernet and
Alert on LAN2 are
enabled.
2. System Board
3. Riser card
17X, 18X 1.C2 Security
175 1.Run Configuration
(See “Setup Utility
program” on
page 241.)
2. System Board
176 1. Covers were removed
from the computer.
177
Corrupted Administrator
Password.
1.System Board
178 1.System Board
183 1.Enter the
administrator
password
184
No RFID Antenna 1. Make sure Asset
Care and Asset ID
are enabled in
Configuration/Setup.
2. RFID Antenna
3. System Board
4. Riser card
185
Corrupted boot sequence. 1. Set configuration and
reinstall the boot
sequence.
186 1.System Board
187 1.Clear Administration
password
2. System Board
189 1. More than three
password attempts
were made to access
the computer.
190
Chassis intrusion detector
was cleared.
This is information only, no
action required.
If this code does not clear:
1.System Board
1XX
Not listed above. 1. System Board
201, 20X
Memory data error. 1. Run Enhanced Diag.
Memory Test
2. Memory Module
3. System Board
225 1.Unsupported Memory
278 IBM PC 300/IntelliStation Vol 3 HMM