
Diagnostic Error Code FRU/Action
000-197-XXX
BIOS test warning  1.Make sure
component that is
called out is enabled
and/or connected
 2. Re-runtest
3. Component that is
called out in warning
statement
4. Component under test
000-198-XXX
BIOS test aborted 1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to the
“Undetermined
problem” section.
000-199-XXX
BIOS test failed, cause
unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test.
 3. Replacecomponent
under function test.
000-250-XXX
BIOS APM failure 1. Flash the system
 2. Systemboard
000-270-XXX
BIOS ACPI failure 1. Flash the system
 2. Systemboard
001-000-XXX
System Test Passed  1.No action
001-00X-XXX
System Error  1.System board
001-01X-XXX
System Error  1.System board
001-024-XXX
System Addressing test
failure
 1.System board
001-025-XXX
System Checksum Value
error
1. Flash the system
 2. Systemboard
001-026-XXX
System FLASH data error 1. Flash the system
 2. Systemboard
001-027-XXX
System Configuration/Setup
error
 1.Run Setup
2. Flash the system
 3. Systemboard
001-032-XXX
System Device Controller
failure
 1.System board
001-034-XXX
System Device Buffer
Allocation failure
1. Reboot the system
2. Flash the system
3. Run memory test
 4. Systemboard
2IBM PC 300/IntelliStation Vol 3 HMM