Diagnostic Error Code FRU/Action
001-035-XXX
System Device Reset
condition detected
1.System board
001-036-XXX
System Register error 1.System board
001-038-XXX
System Extension failure 1.Adapter card
2. Systemboard
001-039-XXX
System DMI data structure
error
1. Flash the system
2. Systemboard
001-040-XXX
System IRQ failure 1.Power-off/on system
and re-test
2. Systemboard
001-041-XXX
System DMA failure 1.Power-off/on system
and re-test
2. Systemboard
001-195-XXX
System Test aborted by
user
1.Information
2. Re-start the test, if
need to
001-196-XXX
System test halt, error
threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
001-197-XXX
System test warning 1. Make sure
component that is
called out is enabled
and/or connected
2. Re-runtest
3. Component that is
called out in warning
statement
4. Component under test
001-198-XXX
System test aborted 1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to “Undetermined
problem” section.
001-199-XXX
System test failed, cause
unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replacecomponent
under function test.
001-250-XXX
System ECC error 1. System board
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System DMA error
1.System board
IBM PC Enhanced Diagnostics error codes 3