Diagnostic Error Code FRU/Action
170-197-XXX
Voltage Sensor(s) test
warning
1.Make sure
component that is
called out is enabled
and/or connected
2. Re-runtest
3. Component that is
called out in warning
statement
4. Component under test
170-198-XXX
Voltage Sensor(s) test
aborted
1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to “Undetermined
problem” section.
170-199-XXX
Voltage Sensor(s) test
failed, cause unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replacecomponent
under function test.
170-250-XXX
170-251-XXX
Voltage Sensor(s) Voltage
limit error
1.Power supply
2. Systemboard
170-254-XXX
Voltage Sensor(s) Voltage
Regulator Module error
1.Voltage Regulator
Module (VRM)
2. Microprocessor
3. Systemboard
175-000-XXX
Thermal Sensor(s) Test
Passed
1.No action
175-0XX-XXX
Thermal Sensor(s) failure 1.Flash system
2. Systemboard
175-195-XXX
Thermal Sensor(s) Test
aborted by user
1.Information
2. Re-start the test, if
need to
175-196-XXX
Thermal Sensor(s) test halt,
error threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
175-197-XXX
Thermal Sensor(s) test
warning
1.Make sure
component that is
called out is enabled
and/or connected
2. Re-runtest
3. Component that is
called out in warning
statement
4. Component under test
18 IBM PC 300/IntelliStation Vol 3 HMM