 001 (continued)
– Insert the IBM PC Enhanced Diagnostics  diskette into
drive A.
– Power-on all external devices.
– Power-on the computer.
– Check for the following response:
1. Readable instructions or the Main Menu.
 Note 
Type 6867 computers default to come  up quiet (No
beep and no memory count and  checkpoint code
display) when no errors are detected  by POST.
To enable Beep and memory count  and checkpoint
code display when a successful POST  occurs:
Enable Power on Status in setup. See “Setup
Utility program” on page 241.
DID YOU RECEIVE THE CORRECT RESPONSE?
Yes  No
002
If the Power Management feature is  enabled, do the
following:
1. Start the Configuration/Setup Utility program
(see “Setup Utility program” on page 241)
2. Select Power Management from the
Configuration/Setup Utility program menu.
 3. Select APM
4. Be sure APM BIOS Mode is  set to Disabled.
If it is not, press Left  Arrow (←) or Right Arrow
(→) to change the setting.
5. Select Automatic Hardware Power
Management.
6. Set Automatic Hardware Power Management
to Disabled.
– or  –
Go to the “IBM PC Enhanced  Diagnostics” on
page 234.
003
Run the IBM PC Enhanced Diagnostics  test. If necessary,
refer to “Diagnostics and test information”  on page 232.
If you receive an error, replace  the part that the
diagnostic program calls out or go  to “IBM PC
Enhanced Diagnostics” on page 234.
If the test stops and you  cannot continue, replace the
last device tested.
If the computer has incorrect keyboard  responses, go
to “Keyboard” on page 228.
If the printer has incorrect responses,  go to “Printer”
on page 228.
(Step 003 continues)