Diagnostic Error Code FRU/Action
086-199-XXX
Mouse Port interface test
failed, cause unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replace component
under function test.
089-000-XXX
Microprocessor Test Passed 1.No action
089-XXX-XXX
Microprocessor failure 1.Microprocessor(s)
2. System board
089-195-XXX
Microprocessor Test aborted
by user
1.Information
2. Re-start the test, if
need to
089-196-XXX
Microprocessor test halt,
error threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
089-197-XXX
Microprocessor test warning 1. Make sure
component that is
called out is enabled
and/or connected
2. Re-run test
3. Component that is
called out in warning
statement
4. Component under test
089-198-XXX
Microprocessor test aborted 1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to “Undetermined
problem” section.
089-199-XXX
Microprocessor test failed,
cause unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replace component
under function test.
170-000-XXX
Voltage Sensor(s) Test
Passed
1.No action
170-0XX-XXX
Voltage Sensor(s) failure 1.Flash system
2. System board
170-195-XXX
Voltage Sensor(s) Test
aborted by user
1.Information
2. Re-start the test, if
need to
170-196-XXX
Voltage Sensor(s) test halt,
error threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
IBM PC Enhanced Diagnostics error codes 17