Diagnostic Error Code FRU/Action
001-260-XXX
001-264-XXX
System IRQ error
1.System board
001-268-XXX
System IRQ1 failure 1. device on IRQ1
2. Systemboard
001-269-XXX
System IRQ2 failure 1. device on IRQ2
2. Systemboard
001-270-XXX
System IRQ3 failure 1. device on IRQ3
2. Systemboard
001-271-XXX
System IRQ4 failure 1. device on IRQ4
2. Systemboard
001-272-XXX
System IRQ5 failure 1. device on IRQ5
2. Systemboard
001-273-XXX
System IRQ6 (diskette
drive) failure
1.Diskette Cable
2. Diskettedrive
3. Systemboard
001-274-XXX
System IRQ7 failure 1. device on IRQ7
2. Systemboard
001-275-XXX
System IRQ8 failure 1. device on IRQ8
2. Systemboard
001-276-XXX
System IRQ9 failure 1. device on IRQ9
2. Systemboard
001-277-XXX
System IRQ10 failure 1. device on IRQ10
2. Systemboard
001-278-XXX
System IRQ11 failure 1. device on IRQ11
2. Systemboard
001-279-XXX
System IRQ12 failure 1. device on IRQ12
2. Systemboard
001-280-XXX
System IRQ13 failure 1. device on IRQ13
2. Systemboard
001-281-XXX
System IRQ14 (hard disk
drive) failure
1. Hard disk drive Cable
2. Hard disk drive
3. Systemboard
001-282-XXX
System IRQ15 failure 1. device on IRQ15
2. Systemboard
001-286-XXX
001-287-XXX
001-288-XXX
System Timer failure
1.System board
001-292-XXX
System CMOS RAM error 1. Run Setup and
re-test
2. Systemboard
001-293-XXX
System CMOS Battery 1.Battery
2. Systemboard
001-298-XXX
System RTC date/time
update failure
1. Flash the system
2. Systemboard
001-299-XXX
System RTC periodic
interrupt failure
1.System board
4IBM PC 300/IntelliStation Vol 3 HMM