Module test menu and hardware
configuration report
Depending on the diagnostics version level  you are using,
the installed devices in the computer  are verified in one of
two ways:
1. At the start of the diagnostic  tests, the Module Test
Menu is displayed. Normally, all installed devices in
the computer are highlighted on the  menu.
2. At the start of the diagnostic  tests, the main menu
appears. From this menu, select System Info then
select Hardware Configuration from the next  menu.
Normally, all installed devices in the  computer are
highlighted on this report.
If an installed device is not  recognized by the diagnostics
program:
The diagnostic code for the device  is not on the
diagnostic diskette. Run the diagnostics provided
with that device.
The missing device is defective or  it requires an
additional diskette or service manual.
An unrecognizable device is installed.
A defective device is causing another  device not to be
recognized.
The SCSI controller failed (on the  system board or
SCSI adapter).
Use the procedure in “Undetermined problem”  on
page 294 to find  the problem.
If a device is missing from  the list, replace it. If this does
not correct the problem, use the  procedure in
“Undetermined problem” on page 294.
    IntelliStation - 6867 227