0031-613 0031-619
0031-613 Unable to send command to task
number
Explanation: An error occurred in sending the poe command to the indicated task.
Probably the remote node is no longer accessible. POE terminates.
User Response: Verify that the remote node in the partition can be contacted by other
means. If problem persists, gather information about the problem and follow local site
procedures for reporting hardware and software problems.
0031-614 Unable to send single command to task
number
Explanation: An error occurred in sending the poe command to the indicated task.
Probably the remote node is no longer accessible. POE terminates.
User Response: Verify that the remote node in the partition can be contacted by other
means. If problem persists, gather information about the problem and follow local site
procedures for reporting hardware and software problems.
0031-615 strappend failed for
string
, rc =
number
Explanation: The internal string append function failed. The system terminates.
User Response: Probable PE error. Gather information about the problem and follow local
site procedures for reporting hardware and software problems.
0031-616 gethostbyname failed for home node
Explanation: The internal gethostbyname function failed. The system terminates.
User Response: Probable PE error. Gather information about the problem and follow local
site procedures for reporting hardware and software problems.
0031-617 pm_getcwd failed, rc =
number
Explanation: The internal pm_getcwd function failed. A return code of 1 implies either
can't open pipe to ksh or command failed. A return code of 2 means the working directory
string is longer than bufsize. The system terminates.
User Response: Probable PE error. Gather information about the problem and follow local
site procedures for reporting hardware and software problems.
0031-618 The following nodes were not contacted:
Explanation: See message 0031-623 for a list of the remote nodes that did not respond
during the phase indicated by the code in message 0031-631. It is possible that some nodes
were not tried, so the list doesn't necessarily indicate that all the nodes were unavailable.
POE terminates.
User Response: Probably connectivity to one of the listed nodes has been lost. Verify that
the node can be contacted by other means. If problem persists, gather information about the
problem and follow local site procedures for reporting hardware and software problems.
0031-619
string
Explanation: The text is explanatory text as would be provided by the perror() or psignal()
functions. For perror(), it is the text contained in sys_errlist[errno] for the error errno. For
psignal(), it is the text contained in sys_siglist[signal] for signal signal. A preliminary
0031-
number
message indicates the context.
86 IBM PE for AIX V2R4.0: Messages