0033-1062 0033-2003
0033-1062 dug: socket read for
string
failed Error is
string
Explanation: The dug statistics collection program encountered an error reading the socket
connection to the monitor program.
Error Class: The monitor program has probably terminated.
User Response: Make sure the monitor program is still running and it did not experience a
problem trying to communicate with the dug program.
0033-1063 dug: Monitor program closed the socket connection before
string
was read.
Explanation: The indicated information was not received.
Error Class: The socket was probably closed because the monitor program terminated.
User Response: Make sure the monitor program is running and did not report any
problems trying to communicate with dug.
0033-1064 dug: Monitor program sent back
number
bytes of
string
but
number
bytes
were expected.
Explanation: An invalid amount of data was received from the monitor program.
Error Class: The version of the monitor program is incompatible with the version of dug
running.
User Response: Make sure the right level of dug and the monitor program are running.
0033-1065 dug: socket write of
string
to monitor program failed. Error is
string
Explanation: The dug statistics collection program encountered an error writing the socket
from either the Performance Monitor or the statistics gathering daemon.
Error Class: The socket write() function failed for the indicated reason.
User Response: Correct the specified problem.
0033-1066 dug: Only
number
of
number
bytes of
string
could be written on socket
connection to monitor program.
Explanation: The indicated message was incompletely written to the monitor program
Error Class: The socket was probably closed because the monitor program terminated.
User Response: Make sure the monitor program is still running and did not errors while
contacting dug
0033-2002 Add: meter name was not specified
Explanation: The display meter for a manual configuration was not specified.
Error Class: During the manual creation of an event/display pair, the display meter was not
specified.
User Response: Be sure both the event and the display meter are specified during manual
configuration.
0033-2003 Add: event name was not specified
Explanation: The event widget for a manual configuration was not specified.
Error Class: During the manual creation of an event/display pair, the meter widget was not
specified.
User Response: Be sure both the event and the display meter are specified during manual
configuration.
146 IBM PE for AIX V2R4.0: Messages