0033-1055 Ÿ 0033-1061

0033-1055 digq()::p;oadcast: Unable to get socket interface

flags.

 

Error

is

 

string

 

 

 

 

Explanation:

The performance statistics query program,

digq, was unable to get

interface

flags

 

of

the

socket

in

order

to

locate

broadcast

devices.

 

Error

Class:

The ioctl() function failed for the indicated reason.

 

 

 

User

Response:

 

Gather information about the problem and follow local site proce

reporting

hardware

and

 

software

problems.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0033-1056 Initialize_socket(), Connection to Resource Manager failed

 

 

 

 

 

 

 

 

 

 

 

 

Explanation:

Connection to resource manager failed.

 

 

 

 

 

 

 

 

 

 

Error

Class:

Resource

manager

may

not

be

running.

 

 

 

 

 

 

 

 

 

 

User

Response:

 

Start

Resource

manager

 

daemon.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0033-1057 pm_start_monitor(), Get Time of Day Call

failed(),

Error

is

 

string

 

 

 

 

 

Explanation:

UNIX

gettod

call

failed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User

Response:

 

Refer

to

AIX

system

documentation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0033-1058 Timer_FunctionPM(), Get Time of Day Call

failed(),

Error

is

 

 

 

string

 

 

 

 

 

Explanation:

UNIX

gettod

call

failed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User

Response:

 

Refer

to

AIX

system

documentation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0033-1059

dug:

Only

 

 

number

 

ofnumber

bytes

 

of stringcould

 

be

written

on

socket

 

 

 

 

 

 

connection

to

 

string.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanation:

The

indicated

message

was

incompletely

written

to

dig.

 

 

 

Error

Class:

The

socket

was

probably

closed

because

dig

terminated.

 

 

User

Response:

 

Make sure dig is still

 

running

on

 

the

 

monitored

node.

If

it

ap

contact

local

support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0033-1060

dug:

dig

on

Node

 

string closed

the

socket

connection

before

 

 

string was

 

 

 

 

 

 

read.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanation:

The

indicated

information

was

not

received.

 

 

 

 

 

 

 

Error

Class:

The

socket

was

probably

closed

because

dig

terminated.

 

 

User

Response:

 

Make sure dig is still

 

running

on

 

the

 

monitored

node.

if

it

app

contact

local

support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0033-1061

dug:

dig

on

 

Node

 

string sent

back

number

bytes

 

ofstring but number

bytes

 

 

 

 

 

were expected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanation:

An invalid amount of data

was

received

from

dig.

 

 

 

 

 

Error

Class:

There is probably a version of dig running that

is

incompatible

wi

monitoring routine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User

Response:

 

Make

sure

the

right

level

of

dig

is

 

running on

the

monitored

no

Chapter 6. VT Messages145

Page 161
Image 161