0031-001 0031-018
Chapter 4. POE Messages
0031-001 No man page available for poe
Explanation: User has requested that the poe man page be displayed (via -hoption), but
the /usr/man/cat1/poe.1 file does not exist, or some directory in the path leading to the file
is not searchable.
User Response: Check that the file exists and that all directories in the path leading to the
file are searchable. The pedocs fileset may need to be installed if the file doesn't exist.
0031-002 Error initializing communication subsystem.
Explanation: The remote node terminates.
User Response: Probable PE error. Gather information about the problem and follow local
site procedures for reporting hardware and software problems.
0031-007 Error initializing communication subsystem: return code
number
Explanation: The remote node was unable to initialize its communication subsystem. This
message gives the return code from the function called. The remote node terminates.
User Response: Verify that the communication subsystem is running properly. If the SP
Switch is being used, make sure that the system software is operational.
0031-009 Couldn't integrate VT traces
Explanation: The system continues, but trace files for the Visualization Tool (VT) were not
integrated.
User Response: Check that sufficient space is available for the VT trace files on each
remote node.
0031-011 tcp service
string
unknown
Explanation: The Partition Manager terminates.
User Response: The PM daemon, pmd, is not known to the system. Review the results of
installation to assure that the daemon specified by inetd is startable on each remote node.
0031-012 pm_contact: socket
Explanation: The Partition Manager terminates, as it could not create a socket.
User Response: The message is followed by an explanatory sentence. Check that the
number of sockets required does not exceed the number available.
0031-013 pm_contact: setsockopt
Explanation: The Partition Manager continues, but some socket options may not be set
correctly.
User Response: Probable PE error. Gather information about the problem and follow local
site procedures for reporting hardware and software problems.
0031-018 Couldn't get info for hostname
string
Explanation: The Partition Manager terminates.
User Response: The name mentioned cannot be identified. Check that the host name is
spelled correctly and is known by name to the node on which the Partition Manager is
running. If hostname is blank, allocation has failed.
Copyright IBM Corp. 1996, 1998 51