0031-371 0031-376
|0031-371 Conflicting specification for -msg_api, using
string
.
|Explanation: A batch job using POE was submitted to LoadLeveler with a network
|statement in the Job Command File that contained a specification for messaging API that
|was different than the specification provided to POE via the MP_MSG_API environment
|variable or the -msg_api command line option. The specification used in this case will be
|that which appeared in the network statement.
|User Response: Verify that the specification in the network statement was intended. If it
|was, modify the POE specification to eliminate the warning, if desired.
|0031-372 Cannot run MPI/LAPI job as specified in submit file.
|Explanation: A batch job using POE was submitted to LoadLeveler with a Job Command
|File that did not contain any network statements, and the specification provided to POE
|(using the MP_MSG_API environment variable or the -msg_api command line flag)
|indicated that both MPI and LAPI were being used. For batch jobs using both messaging
|APIs, the network statements must be used.
|User Response: Ensure that use of both messaging APIs was intended. If so, add the
|required network statements. If not, modify the POE specification to indicate the correct
|messaging API.
|0031-373 Using
string
for messaging API.
|Explanation: Informational message to indicate the messaging API being used for the
|batch POE job submitted to LoadLeveler.
|User Response: None.
|0031-374 Conflicting specification for -euilib, using
string
.
|Explanation: A batch job using POE was submitted to LoadLeveler with a network
|statement in the Job Command File that contained a specification for the messaging passing
|library that was different than the specification provided to POE via the MP_EUILIB
|environment variable or the -euilib command line option. The specification used in this case
|will be that which appeared in the network statement.
|User Response: Verify that the specification in the network statement was intended. If it
|was, modify the poe specification to eliminate the warning, if desired.
|0031-375 Using
string
for euilib.
|Explanation: Informational message to indicate the messaging passing library being used
|for the batch POE job submitted to LoadLeveler.
|User Response: None required.
|0031-376 Conflicting specification for -euidevice, using
string
.
|Explanation: A batch job using POE was submitted to LoadLeveler with a network
|statement in the Job Command File that contained a specification for the message passing
|device that was different than the specification provided to POE via the MP_EUIDEVICE
|environment variable or the -euidevice command line option. The specification used in this
|case will be that which appeared in the network statement.
|User Response: Verify that the specification in the network statement was intended. If it
|was, modify the POE specification to eliminate the warning, if desired.