0031-364 0031-370
|0031-364 Contacting LoadLeveler to
string
information for

string

job.
|Explanation: Informational message to user to indicate that LoadLeveler is being used for
|the interactive or batch job.
|User Response: None required.
|0031-365 LoadLeveler unable to run job, reason:
string
|Explanation: LoadLeveler either could not run the interactive job for the reason indicated,
|or, LoadLeveler terminated the interactive job for the reason indicated.
|User Response: Refer to

Using and Administering LoadLeveler

for information on the
|specific reason indicated in the LoadLeveler message that follows this message.
|0031-366 Invalid combination: nodes=
number
, tasks_per_node=
number
,
|procs=
number
.
|Explanation: The combination specified did not result in a mathematical equality -- nodes
|times tasks_per_node must equal procs, when all three are specified.
|User Response: Correct one or more of the specifications to ensure they are
|mathematically consistent.
|0031-367 Invalid combination: tasks_per_node=
number
, procs=
number
.
|Explanation: User specified the options indicated, and tasks_per_node did not divide
|evenly into procs, which is required as described in IBM Parallel Environment for AIX
|Operation and Use, Volume 1.
|User Response: Correct the specifications as described above.
|0031-368 Number of nodes specified (
number
) may not exceed total number of tasks
|(
number
).
|Explanation: User has specified more nodes (using MP_NODES or -nodes) than tasks
|(using MP_PROCS or -procs), which is an error.
|User Response: Correct the specifications so that there are the same or fewer nodes than
|tasks.
|0031-369 Number of tasks or nodes must also be specified when using
|tasks_per_node.
|Explanation: User has specified tasks per node (using MP_TASKS_PER_NODE or
|-tasks_per_node), but has not specified either the number of nodes (using MP_NODES or
|-nodes) or the number of tasks (using MP_PROCS or -procs), which is required as
|described in IBM Parallel Environment for AIX Operation and Use, Volume 1.
|User Response: Provide either of the omitted specifications.
|0031-370 Internal error: invalid taskid (
number
) received from LoadLeveler.
|Explanation: An internal error has occurred.
|User Response: Gather information about the problem and follow local site procedures for
|reporting hardware and software problems.
Chapter 4. POE Messages 79