0031-143 Ÿ 0031-149

0031-143 Could not read message from debug socket.

 

Explanation:

The

 

call

to

read()

failed

when

attempting

to

 

read

a message fro

 

socket.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User

Response:

 

 

None.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0031-144

 

error

creating

directory

for

 

core

files,

reason:

 

<string>

 

 

 

 

 

 

 

 

 

 

 

Explanation:

A

corefile

 

directory

could

not

be

created

for

the

given

reason

 

User

Response:

 

 

Fix reason and rerun job.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0031-145

 

error

changing

to

 

 

string corefile

directory,

reason

 

<string>

 

 

 

 

 

 

 

 

 

 

Explanation:

The

 

core

file

 

could

not

be

dumped

to

the

named

directory

for

 

reason.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User

Response:

 

 

Fix

reason and

rerun

job

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0031-146 MP_CMDFILE is ignored when MP_STDINMODE

 

is

set

to

none

 

 

 

 

 

 

 

 

 

 

 

 

Explanation:

If you setMP STDINMODEthe

 

 

 

environment variable or-stdinmodethe

 

 

 

 

 

 

 

option

 

to

"none",MP_theCMDFILE

 

 

 

environment

variable

-orcmdfilethe

option is

ignored.

 

 

User

Response:

 

 

To eliminate this WARNING message,

you

should

remove

the

 

 

MP_CMDFILE

 

 

setting or specifyMP STDINMODE

 

 

 

,

which

is not

case

sensitive,

to

anothe

 

value

other

than

"none".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0031-147 MP_HOLD_STDIN is ignored when MP_STDINMODE is

 

set

to

 

none

 

 

 

 

 

 

 

 

 

 

 

Explanation:

If you setMP STDINMODEthe

 

 

 

environment variable or-stdinmodethe

 

 

 

 

 

 

 

option

 

to

"none",MP HOLD_STDIN=yes

 

 

 

is

 

ignored.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User

Response:

 

 

To

eliminate

this

WARNING

message,

you

shouldMP HOLD_STDINset

 

 

 

 

 

 

to

"no".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0031-148

 

Using

 

redirected

STDIN

for

program

name

resolution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanation:

You

redirected

stdin

without specifying a program name or command

 

name,

and

you

did

not MP_setSTDINMODEthe

 

 

environment variable or-stdinmodethe

 

 

 

 

 

 

option

 

to

"none".

Because

 

program

 

behavior

is

 

undefined in this case, a war

 

User

Response:

 

 

You should setMP_theSTDINMODE

 

 

environment

variable

or

 

the

 

 

 

-stdinmode

 

 

option to "none". For more details, see

“Managing IBMStandard Input” in

 

Parallel

Environment

for

AIX:

Operation

and

Use,.

Volume

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0031-149

Unable

to

load

 

shared

objects

required

for

LoadLeveler.

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanation:

You

submitted

a

POE

job

via

LoadLeveler

and a shared object or

required for

LoadLeveler

does

not

exist.

This

error

usually

indicates

files

time

have

been

deleted,

 

moved,

or

had

their

permissions

changed.

 

 

One

of

the

following

files

cannot

 

be

accessed:

 

 

 

 

 

 

 

 

 

 

 

/usr/lpp/LoadL/full/lib/llapi_shr.o

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

/usr/lpp/LoadL/full/lib/libllapi.a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User

Response:

 

 

Contact your system administrator to determine if the files de

above

 

are

 

accessible,

and

correct

if

possible. Otherwise,

gather

informatio

problem

and

follow

 

local

site

procedures

for

reporting

hardware

 

and

software

Chapter 4. POE Messages63

Page 79
Image 79
IBM GC28-1982-02 manual 0031-143 Ÿ, Could not read message from debug socket, String corefile, Set None Explanation