set reInitDelay

Syntax:

set reInitDelay <time> Description:

To set LLDP reInitDelay time Argument:

<Time> : from 1 to 10 second(s)

Possible value:

<Time> : from 1 to 10 second(s)

Example:

FEL2P-SW26(lldp)# set reInitDelay 5

FEL2P-SW26(lldp)#

set tlv

Syntax:

set tlv <0> <1> <2> <3> <4> <range> Description:

To set disable/enable lldp tlv Argument:

Port Description:

bit 0

System Name:

bit 1

System Description: bit 2

System Capabilities: bit 3

Management Address: bit 4

port range syntax : 1,5-7, available from 1 to 10, <Port Description>: 0/1, <System

Name> :0/1, <System Description> : 0/1, < System Capabilities>: 0/1, <

Management Address>: 0/1

Possible value:

<Port Range> : syntax : 1,5-7, available from 1 to 10

Example:

FEL2P-SW26(lldp)# set tlv 1 1 1 1 1 1-10

FEL2P-SW26(lldp)#

set txDelay

Syntax:

set txDelay <time> Description:

To set lldp txdelay Argument:

<time>: from 1 to 8192 second(s)

Possible value:

<time>: from 1 to 8192 second(s)

Example:

FEL2P-SW26(lldp)# set txDelay 500

227