Syntax:

cable <port>

Description:

To enable cable diagnostic function on switch

Argument:

<port> : syntax: 1,5-7, available from 1 to 26

Possible value:

<port> : 1 to 26.

Example:

FEL2P-SW26(diag)# cable 1-5

port 1: cable Ok (2 pairs, length +/- 10 meters) pair A Ok, length 10 meters

pair B Ok, length 10 meters

diag

Syntax:

diag

Description:

Diag is used to test whether EEPROM, UART, DRAM and Flash is normal or not.

Argument:

None.

Possible value:

None.

Example:

FEL2P-SW26 (diag)# diag

EEPROM Test : OK

UART Test : OK

DRAM Test : OK

Flash Test : OK

Loopback

Syntax:

loopback

Description:

For Internal/External Loopback Test.

Argument:

None.

Possible value:

None.

Example:

FEL2P-SW26(diag)# loopback

Internal Loopback Test : OK

External Loopback Test : Port 2 3 4 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Fail

201

Publication date: March., 2011

 

Revision A1

Page 213
Image 213
ICP DAS USA MSM-6226 user manual Diag, Loopback, 201