Note: The switch’s serial port default settings are listed as follows:

Baud rate

57600

Stop bits

1

Data bits

8

Parity

N

Flow control

none

4.When you complete the connection, then press <Enter> key. The login prompt will be shown on the screen. The default username and password are shown as below:

Username = admin

Password = admin

Set IP Address, Subnet Mask and Default Gateway IP Address

Please refer to Fig. 2-7 CLI Management for details about ICPDAS Manufacture’s setting. They are default setting of IP address. You can first either configure your PC IP address or change IP address of the switch, next to change the IP address of default gateway and subnet mask.

For example, your network address is 10.1.1.0, and subnet mask is 255.255.255.0. You can change the switch’s default IP address 192.168.1.1 to

10.1.1.1and set the subnet mask to be 255.255.255.0. Then, choose your default gateway, may be it is 10.1.1.254.

 

Default Value

MSM-6226

Your Network Setting

 

 

 

 

 

IP Address

192.168.1.1

10.1.1.1

 

Subnet

255.255.255.0

255.255.255.0

 

Default Gateway

192.168.1.254

10.1.1.254

 

 

 

 

Table 2-3

After completing these settings in the switch, it will reboot to have the configuration taken effect. After this step, you can operate the management through the network, no matter it is from a web browser or Network Management System (NMS).

Fig. 2-8 the Login Screen for CLI

 

15

Publication date: March., 2011

 

Revision A1

Page 27
Image 27