3 Troubleshooting
If there is an operating problem with the Express Switching Hub, incorrect configuration or cabling is probably the cause. Try the troubleshooting steps below in order:
1Verify that your cables are wired correctly. This is the most common problem. Use a UTP crossover cable to directly connect another switch, server, or workstation to the switch. Use a straight- through cables when connecting to a repeater. See page 8 for more information.
2Make sure the unit is plugged into a grounded, functioning AC outlet providing between 90 VAC and 264 VAC at 50/60 Hz.
3Review the Link LEDs of other devices to ensure that those ports you believe should be functioning are properly attached to the switch with a Category 5 UTP cable.
4Review the switch’s Link LEDS to ensure that ports you believe should be functioning are properly configured, and not disabled or partitioned.
5If you configured a port for full duplex, make sure the device on the other end is configured for full duplex and is capable of transmitting in full duplex. Remember, you must have a
59