Design and Environmental Specifications

Intel® Server Boards S5000PSL and S5000XSL TPS

 

 

 

 

 

 

 

Pin

Signal Name

 

Description

 

 

10

GND

 

Ground

 

 

 

 

 

 

 

 

11

TP_VID_CONN_B11

 

No connection

 

 

 

 

 

 

 

 

12

V_IO_DDCDAT

 

DDCDAT

 

 

 

 

 

 

 

 

13

V_IO_HSYNC_CONN

 

HSYNC (horizontal sync)

 

 

 

 

 

 

 

 

14

V_IO_VSYNC_CONN

 

VSYNC (vertical sync)

 

 

 

 

 

 

 

 

15

V_IO_DDCCLK

 

DDCCLK

 

 

 

 

 

 

 

5.5.2NIC Connectors

The server board provides two stacked RJ45 / 2xUSB connectors side-by-side on the back edge of the board (JA6A1, JA6A2). The pin-out for NIC connectors are identical and are defined in the following table.

Table 24. RJ-45 10/100/1000 NIC Connector Pin-out (JA6A1, JA6A2)

Pin

Signal Name

1

GND

 

 

2

P1V8_NIC

 

 

3

NIC_A_MDI3P

 

 

4

NIC_A_MDI3N

 

 

5

NIC_A_MDI2P

 

 

6

NIC_A_MDI2N

 

 

7

NIC_A_MDI1P

 

 

8

NIC_A_MDI1N

 

 

9

NIC_A_MDI0P

 

 

10

NIC_A_MDI0N

 

 

11 (D1)

NIC_LINKA_1000_N (LED

 

 

12 (D2)

NIC_LINKA_100_N (LED)

 

 

13 (D3)

NIC_ACT_LED_N

 

 

14

NIC_LINK_LED_N

 

 

15

GND

 

 

16

GND

 

 

5.5.3IDE Connector

The server board provides one legacy IDE ATA100 40-pin connector (J2J2). The pin-out is defined in the following table.

Table 25. IDE 40-pin Connector Pin-out (J2J2)

Pin

Signal Name

Pin

Signal Name

1

ESB_PLT_RST_IDE_N

2

GND

 

 

 

 

3

RIDE_DD_7

4

RIDE_DD_8

 

 

 

 

5

RIDE_DD_6

6

RIDE_DD_9

 

 

 

 

60

Revision 1.2

 

Intel order number: D41763-003