8.1Server Boards S5000PSL and S5000XSL Design Specifications
The operation of the server boards at conditions beyond those shown in the following table may cause permanent damage to the system. Exposure to absolute maximum rating conditions for extended periods may affect system reliability.
Table 37. Server Board Design SpecificationsOperating Temperature | 0º C to 55º C 1 (32º F to 131º F) |
|
|
DC Voltage | ± 5% of all nominal voltages |
|
|
Shock (Unpackaged) | Trapezoidal, 50 G, 170 inches / sec |
|
|
Shock (Packaged) |
|
<20 pounds | 36 inches |
20 to <40 pounds | 30 inches |
40 to <80 pounds | 24 inches |
80 to <100 pounds | 18 inches |
100 to <120 pounds | 12 inches |
120 pounds | 9 inches |
|
|
Vibration (Unpackaged) | 5 Hz to 500 Hz 3.13 g RMS random |
|
|