Intel® Server Boards S5000PSL and S5000XSL TPS | Design and Environmental Specifications |
5.5.5SATA / SAS Connectors
The server board provides up to six SATA / SAS connectors:
The pin configuration for each connector is identical and is defined in the following table.
Table 27. SATA / SAS Connector Pin-out (J1J1, J1H2, J1H1, J1G2, J1G1, J1F2)
Pin | Signal Name | Description |
1 | GND | Ground |
|
|
|
2 | SATA/SAS_TX_P_C | Positive side of transmit differential pair |
|
|
|
3 | SATA/SAS_TX_N_C | Negative side of transmit differential pair |
|
|
|
4 | GND | Ground |
|
|
|
5 | SATA/SAS_RX_N_C | Negative side of receive differential pair |
|
|
|
6 | SATA/SAS_RX_P_C | Positive side of receive differential pair |
|
|
|
7 | GND | Ground |
|
|
|
5.5.6Serial Port Connectors
The server board provides one external DB9 Serial A port (J7A1) and one internal
Table 28. External DB9 Serial A Port Pin-out (J7A1)
Pin | Signal Name | Description |
1 | SPA_DCD | DCD (carrier detect) |
|
|
|
2 | SPA_SIN_L | RXD (receive data) |
|
|
|
3 | SPA_SOUT_N | TXD (Transmit data) |
|
|
|
4 | SPA_DTR | DTR (Data terminal ready) |
|
|
|
5 | GND | Ground |
|
|
|
6 | SPA_DSR | DSR (data set ready) |
|
|
|
7 | SPA_RTS | RTS (request to send) |
|
|
|
8 | SPA_CTS | CTS (clear to send) |
|
|
|
9 | SPA_RI | RI (Ring Indicate) |
|
|
|
Revision 1.2 | 63 |