7.Power down and remove the AC power cord.
8.Open the server chassis.
9.Move jumper from the enabled position, covering pins 2 and 3 to the disabled position, covering pins 1 and 2.
10.Close the server chassis.
11.Reconnect the AC cord and power up the server.
Note: Normal BMC functionality is disabled with the Force BMC Update jumper is set to the enabled position. The server should never be run with the BMC Force Update jumper set in this position. This jumper setting should only be used when the standard firmware update process fails. This jumper should remain in the default / disabled position when the server is running normally.
6.3BIOS Select Jumper
The jumper block at J1C3, located at the left of
The rolling BIOS feature of the server board will automatically alternate the boot BIOS to the secondary bank if the BIOS image in the primary bank is corrupted and cannot boot.