Design and Environmental Specifications

Intel® Server Boards S5000PSL and S5000XSL TPS

The bi-color System Status LED operates as follows:

 

 

 

Table 36. System Status LED

 

 

 

 

 

 

Color

State

Criticality

 

 

Description

Off

N/A

Not ready

 

AC power off

Green /

Alternating

Not ready

 

Pre DC Power On – 20-30 second BMC Initialization when AC is

Amber

Blink

 

 

applied to the server. Control Panel buttons are disabled until BMC

 

 

 

 

initialization is complete.

Green

Solid on

System OK

 

System booted and ready.

Green

Blink

Degraded

 

System degraded

 

 

 

 

Unable to use all of the installed memory (more than one

 

 

 

 

 

DIMM installed).

 

 

 

 

Correctable errors over a threshold of 10 and migrating to a

 

 

 

 

 

spare DIMM (memory sparing). This indicates that the user

 

 

 

 

 

no longer has spared DIMMs indicating a redundancy lost

 

 

 

 

 

condition. Corresponding DIMM LED should light up.

 

 

 

 

In mirrored configuration, when memory mirroring takes

 

 

 

 

 

place and system loses memory redundancy. This is not

 

 

 

 

 

covered by (2).

 

 

 

 

Redundancy loss such as power-supply or fan. This does

 

 

 

 

 

not apply to non-redundant sub-systems.

 

 

 

 

PCI-e link errors

 

 

 

 

CPU failure / disabled – if there are two processors and one

 

 

 

 

 

of them fails

 

 

 

 

Fan alarm – Fan failure. Number of operational fans should

 

 

 

 

 

be more than minimum number needed to cool the system

 

 

 

 

Non-critical threshold crossed – Temperature and voltage

Amber

Blink

Non-critical

 

Non-fatal alarm – system is likely to fail

 

 

 

 

Critical voltage threshold crossed

 

 

 

 

VRD hot asserted

 

 

 

 

Minimum number of fans to cool the system not present or

 

 

 

 

 

failed

 

 

 

 

In non-sparing and non-mirroring mode if the threshold of

 

 

 

 

 

ten correctable errors is crossed within the window

 

 

 

 

 

Amber

Solid on

Critical, non-

 

Fatal alarm – system has failed or shutdown

 

 

recoverable

 

DIMM failure when there is one DIMM present, no good

 

 

 

 

 

memory present

 

 

 

 

Run-time memory uncorrectable error in non-redundant

 

 

 

 

mode

 

 

 

 

IERR signal asserted

 

 

 

 

Processor 1 missing

 

 

 

 

Temperature (CPU ThermTrip, memory TempHi, critical

 

 

 

 

 

threshold crossed)

 

 

 

 

No power good – power fault

 

 

 

 

Processor configuration error (for instance, processor

 

 

 

 

 

stepping mismatch)

7.3.1System Status LED – BMC Initialization

When the AC power is first applied to the system and 5V-STBY is present, the BMC controller on the server board requires 5-10 seconds to initialize. During this time, the system status LED will blink, alternating between amber and green, and the power button functionality of the control panel is disabled preventing the server from powering up. Once

74

Revision 1.2

 

Intel order number: D41763-003