Maintaining Your Server

8.Insert new Power Distribution Board into power supply cage (letter “A”). Try to route the power cables to the appropriate area at the time of insertion (see Steps 9 and 10 below). Position the Power Distribution Board on the four standoffs inside the power supply cage. Push down on the Power Distribution Board to securely attach it to the standoffs (letter “B”). Tighten thumb screw (letter “C”).

B

C

A

TP00693

Note: Cables on back of Power Distribution Board not shown to clarify insertion process.

Figure 58. Securing Power Distribution Board to Power Supply Cage

9.Route the P1, P2, and P14 power cables to the server board and connect to appropriate connectors. Refer to the Intel® Server Board Quick Start User’s Guide or User Guide for the location of power connectors.

10.Route the longest power cables (P8, P9, P10, and P11) to the six-drive bay and connect power cables to any installed devices. Route the shorter cables (P3, P4, and P5) to the upper device bay and connect to any installed devices. Route the P6 and P7 cables to the four-drive bay and connect to any installed devices. Route the SATA drive power cables to whichever drive bay is using SATA fixed drives.

50

Intel® Server Chassis SC5300 User Guide

Page 68
Image 68
Intel SC5300 LX, SC5300 BRP manual Securing Power Distribution Board to Power Supply Cage