Code

Description

 

 

 

0xE2

Initial memory found, configured, and installed correctly

 

 

 

 

 

 

 

 

0xE,

Reserved for initialization module use (PEIM)

 

 

 

0xE3

 

 

 

 

 

 

 

 

DXE Core:

0xE4 Entered EFI driver execution phase (DXE)

0xE5 Started dispatching drivers

0xE6 Started connecting drivers

DXE Drivers:

0xE7

Waiting for user input

0xE8

Checking password

 

 

0xE9

Entering the BIOS setup

 

 

0xEA

Flash update

 

 

0xEE

Calling Int 19. One beep unless silent boot is enabled.

 

 

0xEF

Unrecoverable Boot failure/S3 resume failure

 

 

Runtime

Phase/EFI OS Boot:

 

 

0xF4

Entering Sleep state

 

 

0xF5

Exiting Sleep state

 

 

0xF8

OS has requested EFI to close boot services

 

 

0xF9

OS has switched to virtual address mode

 

 

0xFA

OS has requested the system to reset

 

 

PEIM/Recovery:

0x30 Crisis recovery has been initiated because of a user request

0x31 Crisis recovery has been initiated by software (corrupt flash)

0x34 Loading crisis recovery capsule

0x35 Handing off control to the crisis recovery capsule

0x3F Unable to complete crisis recovery.

12.1.2CPU Diagnostic LEDs

The BMC provides one amber LED per processor. The LEDs are turned on when a CPU has an error.

Table 90. Processor Diagnostic LED Locations

LED Reference Designator

Processor

DS5C1

1

DS5C2

2

 

 

DS5C3

3

DS5C4

4

 

 

Revision 1.0