![](/images/backgrounds/109825/109825-132125x1.png)
Intel® Server Board Set SE8500HW4 | Error Handling | |||
|
|
|
|
|
| Code | Description |
|
|
| 0xE2 | Initial memory found, configured, and installed correctly |
|
|
|
|
|
|
|
| 0xE, | Reserved for initialization module use (PEIM) |
|
|
| 0xE3 |
|
|
|
|
|
|
|
|
DXE Core:
0xE4 Entered EFI driver execution phase (DXE)
0xE5 Started dispatching drivers
0xE6 Started connecting drivers
DXE Drivers:
0xE7 | Waiting for user input |
0xE8 | Checking password |
|
|
0xE9 | Entering the BIOS setup |
|
|
0xEA | Flash update |
|
|
0xEE | Calling Int 19. One beep unless silent boot is enabled. |
|
|
0xEF | Unrecoverable Boot failure/S3 resume failure |
|
|
Runtime | Phase/EFI OS Boot: |
|
|
0xF4 | Entering Sleep state |
|
|
0xF5 | Exiting Sleep state |
|
|
0xF8 | OS has requested EFI to close boot services |
|
|
0xF9 | OS has switched to virtual address mode |
|
|
0xFA | OS has requested the system to reset |
|
|
PEIM/Recovery:
0x30 Crisis recovery has been initiated because of a user request
0x31 Crisis recovery has been initiated by software (corrupt flash)
0x34 Loading crisis recovery capsule
0x35 Handing off control to the crisis recovery capsule
0x3F Unable to complete crisis recovery.
12.1.2CPU Diagnostic LEDs
The BMC provides one amber LED per processor. The LEDs are turned on when a CPU has an error.
Table 90. Processor Diagnostic LED Locations
LED Reference Designator | Processor |
DS5C1 | 1 |
DS5C2 | 2 |
|
|
DS5C3 | 3 |
DS5C4 | 4 |
|
|
Revision 1.0 | 113 |
| Intel order number |