226 Ion Operations Manual
Manual Master Cue Lists
Manual master is an additional condition for cue playback. In this mode, cues are triggered
manually by faders without using the [Go] button. With a cue list on a fader set to manual master,
a cue will fire in manual time when the fader is moved from 0% or from Full. This is all done without
hitting [Go]. Any cues in a manual master list not fired by moving a fader, but triggered via [Go]
instead, will fade according to cue’s timings.
To set a cue list to manual master, use the {Fader} softkey in the Cue List Index. To access the cue
list index, press [Cue] [Cue]. {Fader} will toggle between Proportional Master, Intensity Master,
and Manual Master. The default is Proportional Master.
When manual master has been selected as the fader mode for a cue list, the initials ‘MM’ will
appear above the cue list label field. Initials ‘IM’ will display when set to intensity master mode.
Timing is scaled. So, if color has a 5 count delay, and the duration of the cue is 10, the color
transition will not begin until the faders manually reach 50%.
For more information about the other modes available, see Fader type, page 210.
Note:
Follow and hang times will be ignored when firing a cue with a manual master
fader.