RS-232C Interface (Continued)

RS-232C Communication Examples

This section shows the communication examples of RS-232C.

Operating command

Type

Command

Description

 

 

 

Connection

PC→This unit: 21 89 01 00 00 0A

Connection check.

check

This unit→PC: 06 89 01 00 00 0A

 

 

 

 

Power (On)

PC→This unit: 21 89 01 50 57 31 0A

When power is turned on from

This unit→PC: 06 89 01 50 57 0A

standby mode.

 

 

 

 

 

PC→This unit: 21 89 01 50 57 30 0A

When power is turned off

Power (Off)

(standby mode) from power-on

This unit→PC: 06 89 01 50 57 0A

 

mode.

 

 

 

 

 

Input

PC→This unit: 21 89 01 49 50 32 0A

When video input is set to

(COMP.)

This unit→PC: 06 89 01 49 50 0A

component.

 

 

 

Remote

PC→This unit: 21 89 01 52 43 37 33 32 45 0A

When the same operation as

Control

pressing the [MENU] button

This unit→PC: 06 89 01 52 43 0A

(MENU)

on the remote control is made

 

 

 

 

Reference command

Type

 

Command

 

Description

 

 

 

 

 

 

 

PC→This unit: 3F 89 01

50

57

0A

When information of power-

Power (On)

This unit→PC: 06 89 01

50

57

0A

on mode is acquired.

 

This unit→PC: 40

89

01

50

57

31 0A

 

 

 

 

 

 

 

 

 

 

Input

PC→This unit: 3F

89

01

49

50

0A

When information of HDMI 1

This unit→PC: 06

89

01

49

50

0A

(HDMI 1)

input is acquired.

This unit→PC: 40

89

01

49

50

36 0A

 

 

 

 

 

 

 

 

 

 

Others