USING EXTERNAL COMPONENTS

Backup Recording

Backup Recording of the GY-HD250/GY-

HD251’s Camera Image and Sound

Through the IEEE1394 Connector

The GY-HD250/GY-HD251’s camera image and sound can be recorded for backup on another component that is equipped with IEEE1394 connector.

Connections

Use the GY-HD250/GY-HD251 as the master unit.

Connect the master unit and the backup unit with a IEEE1394 cable.

„Backup unit

• Place in HDV/DV signal input mode.

* Depending on the used component, it may be neces- sary to set “REMOTE SELECT”.

When BR-HD50 is used, set the Backup Recording function to OFF.

Also, set REM SEL HDV/DV in the REMOTE[1/2] menu of the BR-HD50 to ON or LOC+REM.

Insert the tape and set to STOP or REC PAUSE status.

CAUTION

Set the IEEE1394 switch on both devices to either HDV or DV.

Start recording after making sure that both devices are properly connected.

If the RET button is pressed during backup recording, output from the IEEE1394 terminal is stopped, the image is switched to the image recorded on this device, inter- rupting the backup recording image.

Connect a Remote Con- trol Unit (RM-LP55/RM- LP57)

Set camera switch functions with the remote control unit (RM-LP55/RM-LP57).

Connection

Connect the remote control unit cable to the REMOTE termi- nal.

CH2-AUDIO OUT-CH1 VIDEO

Notes on Using the Remote Control Unit

When the switch function of this device and the remote

 

control unit are the same, the remote control switch func-

 

tion is prioritized.

FOCUS and ZOOM cannot be adjusted with the remote

 

control unit.

Shutter speed slightly differs from the value displayed on

 

this device.

• Shutter Speed in 24p Mode

 

When this device is in 24p mode, shutter speed cannot be

 

set to 1/60 (U model) or 1/50 (E model) with the remote

 

control unit.

 

Even if shutter speed is set to 1/60 or 1/50 with the remote

 

control unit when in 24p mode, the shutter speed for the

 

device is 1/48.

• When H PHASE adjustment is performed with the remote

 

control unit, only H PHASE of SD signal operates.

When adjusting H PHASE of SD signal with the remote

 

control unit, it cannot be set outside the range of SD H

 

PHASE in the GENLOCK menu screen. X See page 99.

1.

IEEE1394 switch

Operation

Start and stop of recording on the backup unit takes place in accordance with the operation of the REC/VTR trigger button on the master unit.

IEEE 1394

• AUTO WHITE Function

When the device is in VTR mode or during playback or

HEADER REC, the AUTO WHITE function does not work

even if the auto white operation is performed with the RM-

LP55 and RM-LP57.

Master unit GY-HD250/ GY-HD251

VIDEO

CH2-AUDIO OUT-CH1

IEEE 1394

 

Backup unit

Signal flow

IEEE1394 cable

 

(Depending on the GY-HD250/GY-HD251 or the backup unit, the image, audio, and/or time code may deviate from what they should be at the points where the recording is started or stopped.)

MEMO

When the backup recording is started, the “TRIGGER

 

TO DV” or “TRIGGER TO HDV” indication is shown on

 

the LCD or in the viewfinder for approx. 3 seconds.

When the Series Recording function of BR-HD50 is

 

used, the GY-HD250/GY-HD251’s 1394 REC TRIG. item

REMOTE

RM-LP55

CAUTION

Turn the power OFF when connecting.

Operation

1. Turn the device ON.

In the case of the RM-LP55, “LOW LIGHT ERROR” is dis-

played on the LCD screen of the RM-LP55.

Settings

„Master unit (GY-HD250/GY-HD251)

1.Set the IEEE1394 switch on left side of the GY-HD250/ GY-HD251.

DV : When backup in DV format

HDV : When backup in HDV format

2.Place in Camera mode.

3.Set the 1394 REC TRIG. item on the OTHERS[2/2] menu screen. X See page 97.

For HDV mode, set the BACK SPACE [HDV] item. X See page 97.

OTHERS[2/2] menu screen

should be set to OFF.

• If the backup device is equipped with a feature to record

time codes input from the IEEE1394 connector (TC

DUPLICATE feature), time code data the same as on the

master side can be recorded.

If the master unit tape is paused or stopped when the

master unit time code running mode is in REC RUN

mode, the time code for the slave unit stops.

• When using BR-HD50 as a backup device and switching

GY-HD250/GY-HD251 from the playback mode to the

record mode, noise will be noticed on the monitor output

screen of BR-HD50 (backup will be correctly recorded).

2. Turn ON the OPERATE switch on remote control unit to

activate the remote control unit.

See page 72 for details on functions that can be operated

with the remote control unit.

70

71

Page 95
Image 95
JVC GY-HD200CHE, GY-HD200E, GY-HD200CHU, GY-HD200U manual Backup Recording, Connect a Remote Con- trol Unit RM-LP55/RM- LP57