No. 52012
HV-29LP
Z
25
Item Measuring
instrument Test point Adjustment part Description
7.COLOUR
(PAL/SECAM/NT SC)
[Method of adjustment using measuring instrument]
(PAL COLOUR)PAL COLOUR
1. Receive a PAL fu ll fi eld co lour bar s ignal (75 % whi te).
2. Select 2. V/C fr om the SE RVIC E MENU.
3. Select 7.COLO UR with th e function U P/DOWN k ey.
4. Set the init ial setti ng valu e of PAL CO LOUR wit h the func tion
LEFT/RIGHT key.
5. Connect th e oscil losc ope be twee n TP -47B and TP -E
6. Adjust P AL COLOUR and bring the value of (A) in the
illustration to +5V (volt age diff erence betwee n white ( w) an d
cyan (Cy)).
7. Press the MENU/OK key and memorize the setting value.
(SECAM CO LOUR)SECAM COLOUR
1. Receive a SEC AM fu ll field c olou r bar sign al(75 % whi te).
2. Select 2. V/C fr om the SE RVIC E MENU.
3. Select 7.COLO UR with th e function U P/DOWN k ey.
4. Set the initial setting value of SECAM COLOUR with the
function LEFT/ RIGHT k ey.
5. Adju st SECAM COL OUR and br ing the val ue of (A) of the
illustration to +5V(WCy).
6. Press the MENU/OK key and memorize the setting value.
(NTSC 3.58 COLOUR)
1. Input a NTSC 3.58MHz COMPOSITE VIDEO signal (full field
colour bar with 75% whi te) fr om the EXT t erminal.
2. Select 2. V/C fr om the SE RVIC E MENU.
3. Select 7.COLO UR with th e function U P/DOWN k ey.
4. Set the in itial s etting value of NTS C 3.58 COLOUR w ith th e
function LEFT/ RIGHT k ey.
5. Adjust NT SC 3.58 CO LOUR and br ing th e value of (A) of the
illustration to +12V(WCy).
6. Press the MENU/OK key and memorize the setting value.
(NTSC 4.43 COLOUR)
Adju s t men t
of SUB
COLOUR
Signal
generator
Oscilloscope
Remote
control unit
TP-47B
TP-E(#
##
#)
[CRT
SOCKET
PWB ]
NTSC COLOUR
1. Input a NT SC 4.43MHz COMPO SITE VID EO signal (full fi eld
colour bar with 75% whi te) fr om the EXT t erminal.
2. Select 2. V/C fr om the SE RVIC E MENU.
3. Select 7.COLO UR with th e function U P/DOWN k ey.
4. Set the in itial s etting value of NTS C 4.43 CO LOUR w ith the
function LEFT/ RIGHT k ey.
5. Adjust NTS C 4.43 CO LOUR and br ing the value of (A) of the
illustration to +12V(WCy).
6. Press the MENU/OK key and memorize the setting value.
(+)
(-)
0
WCyMgB
(A)