12 Connections & Installation (continued)

EN

Point-to-Point Communication System (continued)

Use twisted-pair cables for the connections.

Duplex

When the camera is controlled using the full duplex protocol,

set the Switch 5 of the Setting switch to ON.

Camera

Controller

RX +

 

TX +

RX -

 

TX -

TX +

 

RX +

TX -

 

RX -

Four wires must be connected.

 

Example (connection with an RM-P2580)

 

Camera

RM-P2580

RX +

C

C TX +

RX -

D

D TX -

TX +

A

A RX +

TX -

B

B RX -

Simplex

When the camera is controlled using the simplex transmission protocol, set the Switch 5 of the Setting switch

to ON.

Camera

Controller

RX +

TX +

RX -

TX -

Two wires must be connected.

Page 12
Image 12
JVC LWT0254-001B-H manual Duplex, Example connection with an RM-P2580, Simplex