JVC LWT0254-001B-H manual Multi-Drop Communication System, Connections & Installation

Models: LWT0254-001B-H

1 44
Download 44 pages 47.73 Kb
Page 9
Image 9

Connections & Installation

9

EN

Multi-Drop Communication System

A system that employs the RM-P2580 as the controller.

The following figure shows a system that can accommodate up to eight cameras. (100 positions can be preset per camera.)

Camera 1

Control signal cable

TK-C625

Coaxial cable

 

AC 24 V power

MACHINE ID: 01

supply

Switch 8: OFF

A CAUTIONS

(RX TERM)

 

Camera 2

 

Observe the following points when connecting components together:

Turn all the components off before proceeding.

Read the instruction manuals of all components before proceeding.

For the types and lengths of connection cables, see ACable ConnectionsB (A pg. 16).

Do not connect the control signal cables in a loop.

TK-C625

 

 

 

 

 

 

 

 

 

 

 

CAUTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The AC 24 V power supply must be isolated from the

 

AC 24 V power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

primary line. (ISOLATED POWER ONLY)

MACHINE ID: 02

supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In order to prevent an excessive current flow through

Switch 8: OFF

A CAUTIONS

 

 

 

 

 

 

 

 

(RX TERM)

 

 

 

 

 

 

 

 

 

 

 

 

the power supply wire or camera due to a short circuit,

 

 

 

 

 

 

 

 

 

 

 

 

 

a fuse must be installed in the power supply line.

Camera 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TK-C625

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC 24 V power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MACHINE ID: 08

supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A CAUTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch 8: ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(RX TERM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO CAMERA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitor

 

 

 

TO CAMERA

 

 

 

COM 1 2

3 4 5 6 7

8 COM 9/1

DATA I / O

 

UNIT CAMERA

COM

SERIAL-1

SERIAL-2

 

 

 

RX+ RX- TX+ TX-

 

 

 

10/2 11/3 12/4 13/5 14/6 15/7 16/8

COM AUTO ALARM COM SW

 

 

 

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote control unit

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIDEO INPUT

 

 

 

 

RM-P2580

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

AC INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MONITOR MONITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIDEO OUTPUT

 

 

 

MONITOR OUTPUT 1

8ACable ConnectionsB (A pg. 16) (Terminal side of Ceiling Mount)

To the TO CAMERA terminal of Control signal cable the RM-P2580 and to the next

camera

Coaxial cable To the CAMERA INPUT terminal

of the RM-P2580

 

To AC 24V power supply

Power cable

Listed class 2 input only

Connection of the control signal cable (A twisted pair cable is recommended.)

8ASwitch SettingsB (A pg. 13)

(Setting switches are on the side of the Ceiling Mount)

Machine ID

Set to the Video Input number of RM-P2580.

(Setting procedures A pg. 14)

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

Switch 1 : Invalid (Set to OFF)

Switch 2 : Invalid (Set to OFF)

Switch 3 : Invalid (Set to OFF)

Switch 4 : ON

Switch 5 : OFF

Switch 7 : Invalid (Set to OFF)

Camera 1

CONTROL terminals

Camera 2

CONTROL terminals

Camera 3

CONTROL terminals

TX + A

TX - B

RX + C

RX - D

TX + A

TX - B

RX + C

RX - D

TX + A

TX - B

RX + C

RX - D

ARX + RM-P2580 B RX - terminals

CTX + D TX -

Each terminal on the camera and the RM-P2580 is marked , , , or . In order to facilitate understanding and to avoid connection mistakes, it is recommended to connect the terminals carrying the same marks.

Switch 8 : Set to ON only for the camera connected at the end of the control signal cable. Set to OFF for all other cameras.

Camera 1 monitor display at power ON

>> INITIAL PROCESS <<

PAN : - - I - -

TILT : - - I - -

PROTOCOL DUPLEX I D - 01

 

 

 

 

 

 

 

Duplex display

 

ID No. display

 

A<Procedures for Checking

 

 

 

 

Machine ID>B (A pg. 14)

 

 

 

 

Page 9
Image 9
JVC LWT0254-001B-H manual Multi-Drop Communication System, Connections & Installation