Connections & Installation (continued) | 11 |
EN |
Point-to-Point Communication System
The following illustration shows a system in which a remote control unit (or a similar piece of equipment)
controls a single camera.
Video out
Control signal cable
AC 24 V power supply
(A CAUTIONS)
Switch 4 : OFF (Point to Point) Switch 8 : ON (Terminated 110 K)
Monitor
Controller
Observe the following points when connecting components together:
●Turn all the components off before proceeding.
●Read the instruction manuals of all components before proceeding.
8ACable ConnectionsB (A pg. 16) (Terminal side of the Ceiling Mount)
Control signal cable
To controller
Coaxial cable
To monitor
To the AC 24V power
supply. Listed class 2
Power cable input only.
(A CAUTIONS)
8ASwitch SettingsB (A pg. 13)
(Setting switches are on the side of the Ceiling Mount)
Setting not |
|
required | ON |
1 2 3 4 5 6 7 8
Switch 1 : Invalid (Set to OFF)
Switch 2 : Invalid (Set to OFF)
Switch 3 : Invalid (Set to OFF)
Switch 4 : OFF
Switch 5 : Configure in accordance with the requirements of the controller communication system.
Switch 7 : Invalid (Set to OFF)
Switch 8 : ON
MEMO
●If this camera or the cables connected to this camera are used in places subject to strong electromagnetic waves or other forms of magnetism, such as those near a radio or TV transmitter, a power transformer or an electric motor, the picture may suffer from noise and colors may be affected.
●An optionally available controller is required to use a
CAUTIONS
●The AC 24 V power supply must be isolated from the primary line. (ISOLATED POWER ONLY)
●In order to prevent an excessive current flow through the power supply wire or camera due to a short circuit, a fuse must be installed in the power supply line.