Mounting the base (continued)

2.Mount the fall-prevention wire to the base (The fall-prevention wire is not attached)

Remove the fall-prevention wire mounting screw of the base and mount the fall-prevention wire.

Note

Also pay careful attention to the length, strength, wiring and material (insulation quality) of the fall-prevention wire to be used.

For the fall-prevention wire, the inside diameter of the ring section to be mounted on the camera unit should be between R4.1 mm and R6.5 mm, and the outside diameter should be below R12 mm.

3.Mount the fall-prevention wire to a strong location.

Mount the fall-prevention wire to a strong location to prevent fall.

4.Mounting the base

Face the imaging direction mark inside the base (j) in the shooting direction and mount the base. When mounting to a wall, face the imaging direction mark (j) upwards.

Use two R4 mm screws for mounting.

Note

When mounting to a wall, be sure to face the imaging direction mark (j) upwards.

R4 mm screws are not supplied. Use the appropriate type according to the material of the location for mounting.

The two attached screws (M4 8 mm) are for mounting the base to the adapter plate. Do not use them here.

Cable connection

1.Connect the LAN cable (A Pg. 26)2.Connect the power cable, alarm cable and heater cable(A Pg. 24)(A Pg. 26)(A Pg. 27)

Memo

The power cable must not be connected when PoE is used.

When the camera is installed with a heater (sold separately: KA-ZH215), be sure to connect it to AC 24 V power supply.

The AC 24 V power supply should conform to the following : Class 2 only (For USA), Isolated power supply only (For Europe).

3.Wind the waterproof tape

Power cable, alarm cable

LAN cable

2

Solder or crimp

 

Wind the

 

waterproof tape

 

3

Wind the insulation tape

1

10BASE-T/ 100BASE-

3

Fall-prevention wire

TX(PoE) terminal

Base

8 mm

2

 

2 mm

Towards the shooting

4

direction

(Face upwards when

R4 mm screw

mounting to wall)

 

LAN cable

Note

Be careful not to drop the camera when it is removed from the base.

18