Alarm Input/Output Cable Connection

Connect the alarm input/output cables with external devices such as a sensor, buzzer, etc.

Signal name

Cable color

 

 

Alarm input 1

Pink

 

 

Alarm input 2

Blue

 

 

Alarm output 1

Orange

 

 

Alarm output 2

Yellow

 

 

GND

Brown

 

 

Cable to use

Length of 50 m or shorter

UL1007, UL1015 or equivalent products

AWG#22 - AWG#18 or equivalent products

Alarm input/output cables

Solder or crimp

LAN cable

Wind the

waterproofInsulation tape tape 3

Note

Noises from an external source may cause malfunctions even when the cable used is shorter than 50 m. In this case, use a shielded cable or move the cable away from the noise source.

Alarm Input

Connect this terminal to sensor devices, such as an infrared sensor, door sensor, metal sensor, manual switch, etc.

Input requirements

No-voltage relay NPN open collector input

Polarity of input detection can be selected using a software

Make/Break (500 ms and above)

Circuit current at low level: 0.3 mA

Applied voltage at high level: 3.3 V

Camera

 

 

Sensor example (1)

unit

 

 

DC3.3 V Input 1

 

VCC

R

or Input 2

R

 

 

OUT

 

 

 

 

3.3 V

0.3 mA

 

 

GND

GND

 

(Alarm input equivalent circuit)

 

Sensor example (2)

 

 

 

 

 

 

Relay switch etc.

OUT

GND

Alarm Output

Connect this terminal to annunciating devices, such as annunciators, indicators, lights, buzzers, etc.

Output requirements

Equivalent to NPN open collector output (Set the output put logic via the Internet Explorer)

Allowable applied voltage: DC12 V and below

Allowable inflow current: 50 mA

Momentary (100 ms to 5000 ms) output (Set time via the Internet Explorer )

 

 

 

 

Example of

Camera

 

 

 

annunciating

 

 

 

 

 

 

devices

unit

 

 

 

 

 

 

DC 12 V

 

 

Output 1

 

 

 

 

 

 

 

or Output 2 IN

 

R

 

 

 

 

 

 

 

 

GND GND

(Alarm output equivalent circuit)

Note

Connect the GND cable of this camera to the GND of the annunciating device.

27