Alarm Input/Output Cable Connection
Connect the alarm input/output cables with external devices such as a sensor, buzzer, etc.
Signal name | Cable color |
|
|
Alarm input 1 | Pink |
|
|
Alarm input 2 | Blue |
|
|
Alarm output 1 | Orange |
|
|
Alarm output 2 | Yellow |
|
|
GND | Brown |
|
|
●Length of 50 m or shorter
●UL1007, UL1015 or equivalent products
●AWG#22 - AWG#18 or equivalent products
Alarm input/output cables
Solder or crimp
LAN cable
Wind the
waterproofInsulation tape tape 3
Note:
●Noises from an external source may cause malfunctions even when the cable used is shorter than 50 m. In this case, use a shielded cable or move the cable away from the noise source.
Connect this terminal to sensor devices, such as an infrared sensor, door sensor, metal sensor, manual switch, etc.
Input requirements●
●Polarity of input detection can be selected using a software
●Make/Break (500 ms and above)
●Circuit current at low level: 0.3 mA
●Applied voltage at high level: 3.3 V
Camera |
|
| Sensor example (1) |
unit |
|
| |
DC3.3 V Input 1 |
| VCC | |
R | or Input 2 | R | |
|
| OUT | |
|
|
| |
| 3.3 V | 0.3 mA |
|
| GND | GND |
|
(Alarm input equivalent circuit) |
| Sensor example (2) | |
|
|
| |
|
|
| Relay switch etc. |
OUT
GND
Alarm OutputConnect this terminal to annunciating devices, such as annunciators, indicators, lights, buzzers, etc.
Output requirements●Equivalent to NPN open collector output (Set the output put logic via the Internet Explorer)
●Allowable applied voltage: DC12 V and below
●Allowable inflow current: 50 mA
●Momentary (100 ms to 5000 ms) output (Set time via the Internet Explorer )
|
|
|
| Example of | ||||
Camera |
|
|
| annunciating | ||||
|
|
|
|
|
| devices | ||
unit |
|
|
|
|
|
| DC 12 V | |
|
| Output 1 |
|
|
|
|
| |
|
| or Output 2 IN |
| R |
|
| ||
|
|
|
|
|
|
GND GND
(Alarm output equivalent circuit)
Note:
●Connect the GND cable of this camera to the GND of the annunciating device.
27