Setup

Mounting the camera via piping

Use a piping hole to mount the camera.

Use the piping hole at the bottom of the base to mount the camera

1.Remove the camera unit from the base (A Pg. 17)

2.Mount the fall-prevention wire to the base (A Pg. 18)3.Wind the seal tape

Wind the joint (where the threaded portion of the piping hole and the tapped hole of the piping meets) of the piping with seal tape for more than 2 rounds.

4.Mount the base to the piping

Turn the base in a clockwise direction and screw into the piping. (Piping hole: G3/4-14 UNC)

Note

Do not screw in the piping for more than 12 mm deep. Otherwise, it may damage the internal parts of the camera.

5.Secure the base to the ceiling

Use RM4 mm screws (x2) to secure the base tightly to the ceiling.

Check that there is no gap between the ceiling and the base.

Note

RM4 screws are not supplied. Use the appropriate type according to the material of the location for mounting.

The two attached screws (M4 8 mm) are for mounting the base to the adapter plate. Do not use them here.

AMounting the camera via electrical boxB (A Pg. 21)

6.Mount the fall-prevention wire to a strong location (A Pg. 18)

4

Seal tape

12 mm and below

7

Fall-prevention wire

5 3

8 mm

2 mm

6

RM4 mm screw

7.The following procedures are the same as normal mounting

Cable connection (A Pg. 18)

Mounting the camera to the base (A Pg. 19)

Image adjustment (A Pg. 28)

Mounting the inner dome (A Pg. 30)

Mounting the dome cover (A Pg. 30)

22